Title: Firmware update for GP58-CR
Model: GP58-CR
Control Number: FAE_2022010701 Date: 2022/01/07

Technical announcement:
 
Dear Valuable Customers:
ICT would like to inform our valuable customers below information.

 


1. In order to prevent GP58-CR date/setting issue, firmware version before (includes) “GP0XXXXMQ(98DA)” must update it to the latest firmware version “GP0XXXXN0(2686)”.
(Please contact ICT local distributors/branches to get the latest firmware & GP58-CR PC tool.)

 
***The firmware label is showing on CPU board which located in the bottom of GP58-CR, or use GP58-CR PC tool to read out the unit firmware. If your GP-58CR is already experiencing a date/time issue, please perform firmware and tool update using the latest version, regardless of your installed version.
 

 ​I.) Firmware version label is under the transparent cover
 II.) Firmware version read out by GP58-CR PC tool
 ​I.)PCB.png
 II.)TOOL 畫面.png

2. After firmware updated, please use the latest GP58-CR PC tool (as link as below) to check and set again the format layout & other relative settings into GP58-CR, to ensure the settings are correct.
(Please contact ICT local distributors/branches to get the latest firmware & GP58-CR PC tool.)

Note: If you don’t have a setting data (*.g58), you may use GP58-CR PC tool in order to executive a setting data (*.g58) to copy the setting to the rest of GP58-CR(s). 

Product Division
International Currency Technologies Corp.
January 7th, 2022